| Subject: | Re: [LCtalk] help! LanBox LCE falls asleep ? |
| From: | Fokko van Duin |
| Date: | Wed, 27 Sep 2006 09:37:47 +0300 |
At 01:54 +0200 27-09-2006, tim wrote:
Hello,
I have a problem controlling a LanBox LCE and a switchpack from Pure
Data. It works, but it always stops working after 30 seconds or so.
What do you mean with stops working? If you mean lost connection, did
you try with LCedit+?
The connection is made via the [tcpclient] object for pd. I suspect
that the connection is not really lost but the lanbox (or switchpack ?)
falls asleep after 30 seconds. I can wake it up only by breaking the
connection and reconnecting.
An example patch for pd+lanbox has a "keep connection alive" part witch
sends Common16BitMode On (0x65 0xFF) Is this correct ?
Yes.
BTW Where did you get the pd examples, as we do not have them?
It doesn't do the job of keeping the Lanbox active here. Which other
command could work for this?
*00050000# read version and box type
Any other reading command is ok.
--
Fokko van Duin,
CDS advanced technology bv,
http://www.lanbox.com/
|