At 15:21 +0100 17-03-2004, Michael Lohrengel wrote: That makes sense - but it means a hell of a lot of work for me !! Go back to something like 150 logic songs and change each and every one on the computer, then convert it to a midifile and store it back into the midiplayer. Is there anyway to achieve a working system without that hassle ? I mean, I could do without the dynamic layers for my purpose? Sorry, no way. But what I see below is also wrong for a LC+! 1 1 1 1 Control 1 21 1 ctrl 21 1 1 1 1 Control 3 21 1 ctrl 21 1 1 1 1 Control 15 21 0 ctrl 21 No, no. it should have been: 1 1 1 5 Control 1 21 1 ctrl 21 1 1 1 6 Control 1 53 97 (#21 LSB) 1 1 1 7 Control 1 86 11 ctrl 86 1 1 1 8 Control 3 21 1 ctrl 21 1 1 1 9 Control 3 53 97 (#21 LSB) 1 1 1 10 Control 3 86 12 ctrl 86 BTW NOTHING should be send in between a single LanBox command (like this Go xxx.xx). Maybe you can also send a MIDI hex string in logic: b0 15 01 35 61 56 0b is the same as: 1 1 1 1 Control 1 21 1 ctrl 21 1 1 1 2 Control 1 53 97 (#21 LSB) 1 1 1 3 Control 1 86 11 ctrl 86 Intensity must be the first panel, see also tutorial. Panel 1 is special, it must be intensity or if it has no light channel assigned it will be treated as invisible. This has to do with merging of fixtures with and without Intensity, but when grouped you still want to have an intensity control. Also the master intensity only looks to panel 1.